Electric motors use around 45% of the world's electricity, according to the International Energy Agency, yet most plants only see their energy use as a total on the utility bill. Load Controls power sensors measure the true power of each motor, turning that total into machine-level data you can manage, report and act on.
Under the EU Energy Efficiency Directive, larger energy users must carry out regular energy audits or run an energy management system such as ISO 50001, and many customers now ask suppliers for energy and carbon data. Both need measured data, not estimates.
Many motors are oversized so that a machine never stalls. Below about half load, a motor's efficiency and power factor fall, so the plant pays for capacity it does not use and may incur reactive power charges. Most motors run best at roughly 75% to 90% of their rating. Trending power over a full production cycle shows whether a smaller motor could handle the peak while running more efficiently the rest of the time. As an example, a 22 kW motor replaced with a 15 kW one on a suitable duty saves about 7.5 kW, roughly 15,500 kWh a year at 40 hours a week.
Universal Power Cells provide 4–20 mA and 0–10 V signals proportional to power, and the UPC-MB communicates over Modbus, so data flows into your PLC, SCADA or energy management software. Logged in kWh, it supports cost per unit, carbon reporting and verified savings. See IIoT and control system integration.
Further reading: Monitoring and protecting pumps, IIoT and control system integration, Why measure power, not amps
Can power sensors replace a utility sub-meter?
They measure the true power of individual motors rather than a whole supply, which is what you need to find significant energy uses and verify savings machine by machine. Many plants use both.
How do I find out if a motor is oversized?
Log its power over a full production cycle and compare it with the nameplate rating. A motor that spends most of its time below about half load is a candidate for right-sizing or a drive.
Will the data work with our energy management software?
Yes. The sensors output standard 4–20 mA, 0–10 V or Modbus signals, which can be logged by a PLC, SCADA system or energy software.
Can I measure the savings from a new variable frequency drive?
Yes. Install the sensor before the change to set a baseline, then compare. On drive-fed motors the Universal Power Cell is installed on the drive output.

Tell us the application, motor size and drive type. We will recommend a model and send you a quotation. 12-month warranty and support from our team in France.