Industry background

Industries & Applications

Chemical processing

In chemical plants a pump that runs dry or an agitator that loses a blade is a safety issue as well as a repair bill. Load Controls power sensors watch these motors from the control room or motor control centre, with nothing in the process, the pipework or the hazardous area.

Case study: 60 pumps in a chlorine plant

A large chlorine and caustic soda producer in the north-eastern United States uses the mercury cell process, in which 60 pumps circulate mercury through the electrolysis cells. If an impeller detaches or a pump jams, the cell can generate hydrogen, which is potentially explosive. Motor current was not sensitive enough to see impeller loss, because the motors run below half load where current hardly changes.

Load Controls power sensors were installed in the electrical control room, with no changes to pumps or piping. Each has a low trip point for impeller loss and a high trip point for jams, shown on control room and plant floor displays, with an alarm and printout identifying the pump, time and type of trip. Comparing power across all 60 pumps also revealed two incorrectly sized impellers and several oversized motors that could be replaced with lower-consumption units.

Where power monitoring helps

  • Process pumps: dry running, loss of flow, dead head and blocked outlets on centrifugal, positive displacement, magnetic-drive and canned pumps. See monitoring and protecting pumps.
  • Agitators and reactors: power follows viscosity through a reaction and drops if a blade breaks inside a sealed reactor, where an incomplete mix can spoil a batch.
  • Centrifuges and evaporators: load trends show imbalance, fouling and overloads.
  • Infeed control: the power signal can regulate feed so the downstream equipment runs at a steady load.

Safety and validated processes

Several Load Controls sensors are SIL-1 and SIL-2 capable, and the PMP-25 is available with a tamper-proof lockout switch so set points cannot be changed once commissioned. Because the sensors sit in the motor control centre, they avoid the cost of equipment certified for the hazardous area.

Recommended products

Further reading: Agitators and mixers: profiling a process, Certifications, Why measure power, not amps

Frequently asked questions

Do the sensors need to be certified for the hazardous area?

No. They are installed in the motor control centre or control room and measure the motor supply, so nothing is mounted in the hazardous area.

Can it detect a lost impeller?

Yes. Losing an impeller removes most of the pump load, so power falls below the low trip point. In the chlorine plant case study this was the main reason for choosing power over current sensing.

Are the sensors suitable for safety functions?

Several models, including the PMP-25 and TP-2, are SIL-1 and SIL-2 capable. Tell us the safety function and we will confirm the documentation available.

Can I stop operators changing the trip settings?

Yes. The PMP-25 with tamper-proof switch locks the set points once the control is commissioned.

Industry application image

Key applications

  • Pump loss of flow and dry run detection
  • Impeller loss and jam detection
  • Agitator viscosity and broken blade monitoring
  • Centrifuge and evaporator monitoring
  • Infeed control
  • Finding oversized motors and wrong impellers

Case Study: Chlorine Manufacturing

How Load Controls power sensors protect pumps and agitators in chlorine manufacturing — a global chemical processing case study.

View resource →

White Paper: Using Power Sensing to Monitor and Protect Pumps

Trip point set-up for centrifugal, positive displacement and sealless pumps.

View resource →

Need the right sensor for your motor?

Tell us the application, motor size and drive type. We will recommend a model and send you a quotation. 12-month warranty and support from our team in France.

Request a quoteBrowse products